Magni:Protocols/ph

From OpenWetWare
Revision as of 08:44, 18 April 2013 by Lorenzo Pasotti (talk | contribs) (→‎pH adjustment for M9 medium)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Home        Contact        Lab Members        Publications        Research        Internal        Protocols        Data       


pH adjustment for LB medium

  • Before autoclaving the LB medium:
    • dip the pH-meter probe in the medium to monitor pH (wash probe with deionized water and calibrate pH-meter with 2 points when required);
    • ajust pH with HCl, NaOH (or KOH). While handling strong acid/base, always wear suitable protections!
    • wash the pH probe with deionized water and store it in KCl 3M.
  • Autoclave the medium

pH adjustment for M9 medium

  • According to the M9 medium preparation protocol, mix:
    • water,
    • glycerol and
    • M9 salts.
  • Dip the pH-meter probe in the mix to monitor pH (wash probe with deionized water and calibrate pH-meter with 2 points when required);
  • ajust pH with HCl, NaOH (or KOH). While handling strong acid/base, always wear suitable protections!
  • wash the pH probe with deionized water and store it in KCl 3M.
  • Autoclave the mix in a bottle.
  • Equilibrate at room temperature and add the remaining ingredients (casamino acids, thiamine, CaCl2, MgSO4).