IGEM:IMPERIAL/2007/Experimental Design/Phase1/Results 1.2
In vivo Testing of pTet-LuxR-pLux-GFP Construct
Aims
To determine if the pTet-LuxR-pLux-GFP construct works in vivo after induction of 1mM AHL concentration
Tested on 17-08-2007
Materials and Methods
Refer to protocols page.
Results
Test: 17-08-2007
Upon induction, the pTet-LuxR-pLux-GFP construct showed a significant fluorescent signal when compared to the negative control. In addition, the fluorescence levels were comparable to that of the positive control, indicating strong expression of GFP with the construct. |
Controls:
- Positive control - diluted GFP solution of equal volume
- Negative control - LB media of equal volume
Discussion
pTet-LuxR-pLux-GFP
Fig.1 showed that the pTet-LuxR-pLux-GFP construct gave a good amount of expression of GFP (~83000), indicating that the construct is functioning well in vivo. The drawback of this construct, however, is that LuxR levels within the cells are inconsistent, to which this variation would complicate the kinetics of GFP expression. Thus it will be unfair to relate the increase in expression of fluorescence solely due to the increase in induction and strength of the pLux promoter.
There was also significant variability in the results across the different samples, which could be attributed either to experimental methodology, or the intrinsic nature of variability of expression in the in vivo chassis.
Conclusion
To conclude,
- pTet-LuxR-pLux-GFP construct gave a strong fluorescent signal, indicating good expression of GFP in vivo.
- LuxR levels are inconsistent throughout experiment.