IGEM:IMPERIAL/2006/project/Oscillator/project browser/Prey Construct: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
 
Line 66: Line 66:
| Variability  || colspan="2" | Variability at the device population level (day to day, device to device) should be as low as possible.
| Variability  || colspan="2" | Variability at the device population level (day to day, device to device) should be as low as possible.
|}
|}
<html>
<!-- Start of StatCounter Code -->
<script type="text/javascript" language="javascript">
var sc_project=1999441;
var sc_invisible=1;
var sc_partition=18;
var sc_security="18996820";
</script>
<script type="text/javascript" language="javascript" src="http://www.statcounter.com/counter/frames.js"></script><noscript><a href="http://www.statcounter.com/" target="_blank"><img  src="http://c19.statcounter.com/counter.php?sc_project=1999441&amp;java=0&amp;security=18996820&amp;invisible=1" alt="website statistics" border="0"></a> </noscript>
<!-- End of StatCounter Code -->
</html>

Latest revision as of 09:40, 30 October 2006

Super Parts Molecular Prey-Predator Oscillator
Actual Part
Sub Parts Test Sensing Prey Construct <bbpart>C0261</bbpart> <bbpart>I13401</bbpart>



Motivation

  • The Prey Construct must control the molecular activity associated with the Prey in the Lotka-Volterra model.
  • This part has to interface with the Predator-construct.
  • To satisfy the conditions for Lotka-Volterra, this part has to produce the molecular prey exponentially.


Part Interface

INPUTS OUTPUTS
AHL AHL

Expected behavior and performances

System level specifications
Properties Specifications
Input Range(s) Input range should be sufficient to produce a detectable output of prey.
Output Range(s) Output range of the prey should be detectable and sufficient to interact with the predator.
Expected Output

To satisfy Lotka-Volterra conditions, our system should produce prey exponentially.

Robustness Device should work for at least 10 cycles of the oscillator to match system level oscillator specifications.
Variability Variability at the device population level (day to day, device to device) should be as low as possible.

<html> <!-- Start of StatCounter Code --> <script type="text/javascript" language="javascript"> var sc_project=1999441; var sc_invisible=1; var sc_partition=18; var sc_security="18996820"; </script>

<script type="text/javascript" language="javascript" src="http://www.statcounter.com/counter/frames.js"></script><noscript><a href="http://www.statcounter.com/" target="_blank"><img src="http://c19.statcounter.com/counter.php?sc_project=1999441&amp;java=0&amp;security=18996820&amp;invisible=1" alt="website statistics" border="0"></a> </noscript> <!-- End of StatCounter Code --> </html>