Haynes Lab:Notebook/Engineering PC-TFs/2013/10/21: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(3 intermediate revisions by the same user not shown)
Line 6: Line 6:
| colspan="2"|
| colspan="2"|
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
==October 21,2013==
==October 21, 2013==
'''Miniprep liquid cultures'''
<big>''Miniprep liquid cultures''</big>
*Add 100 μL of 7X Lysis Buffer (Blue) to 600 μL of E.coli culture in a 1.5 ml microcentrifuge tube. Mix by inverting tube 4-6times.
*Add 100 μL of 7X Lysis Buffer (Blue) to 600 μL of E.coli culture in a 1.5 ml microcentrifuge tube. Mix by inverting tube 4-6times.
*Add 350 μL of cold Neutralization Buffer (Yellow), mix thoroughly. Neutralization is complete when sample becomes yellow and precipitate has formed.
*Add 350 μL of cold Neutralization Buffer (Yellow), mix thoroughly. Neutralization is complete when sample becomes yellow and precipitate has formed.
Line 17: Line 17:




<big>''Measure concentration of each fragment''</big>:
* Load Gen 5 2.0 software. Go to the Task Manager-Take 3 Application
* Go to Nucleic Acid Quantification.
* Pipette 2 µL of each DNA sequence into Take 3 plate.
* Place plate in EPOCH plate reader.
{| {{table}}
| align="center" style="background:#efefef;"| '''Part'''
| align="center" style="background:#efefef;"|'''Concentration'''
|-
| KAH126 (1)|| 22.239 ng/μL
|-
| KAH126 (2)||57.672 ng/μL
|-
| CMV+MV9 (1)||11.323 ng/μL
|-
| CMV+MV9 (2)||1.92 ng/μL
|-
| CMV+MV9 (3)||27.394 ng/μL
|}


<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### -->

Revision as of 14:13, 25 October 2013



<html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

October 21, 2013

Miniprep liquid cultures

  • Add 100 μL of 7X Lysis Buffer (Blue) to 600 μL of E.coli culture in a 1.5 ml microcentrifuge tube. Mix by inverting tube 4-6times.
  • Add 350 μL of cold Neutralization Buffer (Yellow), mix thoroughly. Neutralization is complete when sample becomes yellow and precipitate has formed.
  • Centrifuge at 11,000-16,000 g for two minutes.
  • Transfer the supernatent into the Zymo-Spin Column. Place column in 2 ml collection tube and centrifuge for 15 seconds at top speed. Discard flow-through.
  • Add 200μL of Endo-Wash Buffer to the column. Centrifuge for 15 seconds at top speed.
  • Add 400μL of Zyppy Wash Buffer to the column. Centrifuge at top speed for 30 seconds.
  • Transfer column to 1.5 microcentrifuge tube and add 50μL of Zyppy Elution Buffer directly to column. Centrifuge for 1 minute at top speed to elute DNA.


Measure concentration of each fragment:

  • Load Gen 5 2.0 software. Go to the Task Manager-Take 3 Application
  • Go to Nucleic Acid Quantification.
  • Pipette 2 µL of each DNA sequence into Take 3 plate.
  • Place plate in EPOCH plate reader.
Part Concentration
KAH126 (1) 22.239 ng/μL
KAH126 (2) 57.672 ng/μL
CMV+MV9 (1) 11.323 ng/μL
CMV+MV9 (2) 1.92 ng/μL
CMV+MV9 (3) 27.394 ng/μL