==Summary==
==Summary==
-
<i>Assembly Check of PCR Reactions 1,2,3,4<i>
+
<i>Assembly Check of PCR Reactions 1,2,3,4
* Gel Electrophoresis
* Gel Electrophoresis
Line 24: Line 24:
*Turn on electrophoresis and let run for thirty minutes.
*Turn on electrophoresis and let run for thirty minutes.
-
<b>The assembly did not work. No bands were seen when placed under UV light.<b>
+
<b>The assembly did not work. No bands were seen when placed under UV light.

Current revision

Engineering PC-TFs Main project page
Previous entry      Next entry

Summary

Assembly Check of PCR Reactions 1,2,3,4

  • Gel Electrophoresis

Follow steps for gel electrophoresis.

  • Orient top notch of gel electrophoresis apparatus. Place gel tray into larger tray.
  • Create 1% gel by putting .6 grams of agarose into flask.
  • Microwave agarose solution for 30 seconds
  • Using hot gloves, grab flask out of microwave and swirl flask vigorously. Place back in microwave for 30 more seconds.
  • When flask is taken out of microwave, make sure that the agarose is completed dissolved.
  • Set up wells on gel electrophoresis apparatus. The mold for the first digest is B-10. Use the thin "teeth" and slip in the notches.
  • Add EtBr (ethidium bromide) to the agarose gel. There should be 1 microliter of EtBr per 10ml of agarose gel. Therefore, 6 µL.
  • Pour gel into tray. Wait twenty minutes for gel to settle.
  • Wash the agarose gel flask.
  • Pipette 15 μL of DNA ladder into first well. Pipette 5μL of PCR reactions into subsequent wells.
  • Turn on electrophoresis and let run for thirty minutes.

The assembly did not work. No bands were seen when placed under UV light.