Endy:Yeast Colony PCR

From OpenWetWare
Revision as of 13:03, 16 February 2006 by Ssutton (talk | contribs)
Jump to navigationJump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Back to Yeast Colony PCR

Method

  1. Using sterile pipette tips, transfer a 1 mm colony into 50 uL of 60 U/ml Zymolyase
    • 3 uL of 1 U/mL Zymolyase stock solution
    • 47 uL of water
  2. Incubate cell suspension at 37 C for 30 minutes.
  3. Incubate cell suspension at 95 C for 10 minutes.
  4. Use 5 uL of the cell suspension for a 50 uL PCR reaction

Zymolase Stock Solution

  • 10,000 U Zymolyase (Sigma)
  • 1 mL KHPO4 buffer, pH 7.5 (adjusted with KOH)
  • 0.2 mL 5M NaCl
  • 5 mL 100% glycerol
  • Add H2O to 10 mL
  • Store at -20 C

Related Topics

Silver: Colony PCR