Endy:F2620: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
No edit summary
 
(4 intermediate revisions by the same user not shown)
Line 5: Line 5:


==Characterization data==
==Characterization data==
{|{{Table}}
!Experiment
!Protocol
!Data
|-
|[[Endy:F2620/Transfer Curve|Transfer Curve]]
|[[Endy:F2620/Transfer Curve/Protocols|protocol]]
|[[Endy:F2620/Transfer Curve/Data|data]]
|-
|[[Endy:F2620/Specificity|Specificity]]
|[[Endy:F2620/Specificity/Protocols|protocol]]
|[[Endy:F2620/Specificity/Data|data]]
|-
|[[Endy:F2620/Latency|Latency]]
|[[Endy:F2620/Latency/Protocols|protocol]]
|[[Endy:F2620/Latency/Data|data]]
|-
|[[Endy:F2620/Stability|Stability]]
|[[Endy:F2620/Stability/Protocols|protocol]]
|[[Endy:F2620/Stability/Data|data]]
|}
*[[Endy:F2620/Experiments Pending|Experiments Pending]]
*[[Endy:F2620/Experiments Pending|Experiments Pending]]
*[[Endy:F2620/Transfer Curve|Transfer Curve]]
*[[Endy:F2620/Specificity|Specificity]]
*[[Endy:F2620/Latency|Latency]]
*[[Endy:F2620/Stability|Stability]]
*[[Endy:F2620/Calibration|Calibration]]
*[[Endy:F2620/Calibration|Calibration]]
*[[Endy:F2620/Machine variation|Machine variation]]
*[[Endy:F2620/Machine variation|Machine variation]]
Line 17: Line 36:
==Communications==
==Communications==
*[[Endy:F2620/Nature Biotech draft|Nature Biotech. draft]]
*[[Endy:F2620/Nature Biotech draft|Nature Biotech. draft]]
*[[Endy:F2620/Figures]]
*[[Nat Biotech Guidelines]]
*[[Nat Biotech Guidelines]]
*[[Endy:F2620/Miscellaneous communications|Other communications]]
*[[Endy:F2620/Miscellaneous communications|Other communications]]
Line 25: Line 45:
*[http://parts.mit.edu/registry/index.php/Part:BBa_F2620 F2620 Registry page]
*[http://parts.mit.edu/registry/index.php/Part:BBa_F2620 F2620 Registry page]
*[[Endy:F2620/Data sheet versions|Other data sheet versions]]
*[[Endy:F2620/Data sheet versions|Other data sheet versions]]
<math>
P_{out} = \frac{P_{max}[3OC_6HSL]^n}{K^n+[3OC_6HSL]^n}
</math>

Latest revision as of 09:26, 11 February 2008

Introduction

Drew's datasheet

We are working to comprehensively characterize a receiver device to enable cell-cell communication. F2620 is a receiver device that responds to the presence of a signaling molecule in the extracellular media by activating transcription from a regulated promoter. Our aims are to provide a well-characterized receiver device to the biological engineering community and secondly to develop a framework for device characterization that can be adapted to characterize other devices that can be used to build modular biological systems. Further details about this work can be found on the cell-cell signaling page of the registry.

Characterization data

Experiment Protocol Data
Transfer Curve protocol data
Specificity protocol data
Latency protocol data
Stability protocol data


Communications

F2620 Data Sheets

[math]\displaystyle{ P_{out} = \frac{P_{max}[3OC_6HSL]^n}{K^n+[3OC_6HSL]^n} }[/math]