Endy:Colony PCR

From OpenWetWare
Jump to navigationJump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

See Colony PCR for general information about this protocol and other variants

Protocol

  • Use a sterile toothpick or pipet tip to resuspend a plated colony in 50 μl sterile water.
  • store the colony resuspension at 4C so you can start cultures if necessary (should be OK for a couple days, if you need it to last longer you should use an Index plate.

Reaction Mix

Use the following reaction mix for each PCR:

  • 1 μl 10x Thermo polymerase buffer
  • 1 μl 10x dNTPs (10x = 2.5 mM each dNTP)
  • 0.15 μl 40 μM FWD primer
  • 0.15 μl 40 μM REV primer
  • 0.1 μl Polymerase (taq or vent)
  • 6.6 μl H2O
  • 1.0 μl template suspension

PCR protocol

  • 95 C for 6 minutes (disrupt cells, separate DNA)
  • Cycle 35 times:
    • 95 C for 30 s (melting)
    • 53 C (or whatever temperature is appropriate) for 30 s (annealing)
    • 72 C for X s (elongation)
  • 72 C for 10 minutes (final elongation)
  • 4 C forever
  • For long amplicons, X = 1 minute + 2.5 s per 100bp
  • For shorter amplicons, under ~1kb, this can be shortened judiciously.