DropBase:droplet generation 4 inlets: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
No edit summary
 
(9 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{DropBase}}
{{DropBase}}


[[Category:Lab]]
[[Category:Protocol]] [[Category:Microfluidics]]
 
<div ...>  
<div ...>  


Line 7: Line 8:
=Overview=
=Overview=


[[Image:10um_2_inlets.png|180px|left]]
[[Image:10um_4_inlets.png|180px|left]]


'''Description & usage notes'''
'''Description'''


&bull; Single aqueous inlet flow-focusing junction <br>
&bull; Triple aqueous inlet flow-focusing junction <br>
&bull; the example shown has a 10 μm wide junction, although templates for a variety of different junction sizes are available to download<br><br>
&bull; the example shown has a 10 μm wide junction, although templates for a variety of different junction sizes are available to download<br><br>


Line 18: Line 19:
Devenish SRA, Kaltenbach M, Fischlechner M, Hollfelder F, ''Droplets as Reaction Compartments for Nanotechnology'' in <u>Protein Nanotechnology</u>, Edited by Gerrard J, Humana Press; '''2013'''.<br><br>
Devenish SRA, Kaltenbach M, Fischlechner M, Hollfelder F, ''Droplets as Reaction Compartments for Nanotechnology'' in <u>Protein Nanotechnology</u>, Edited by Gerrard J, Humana Press; '''2013'''.<br><br>


'''Submitted by''': Martin Fischlechner
'''Submitted by''': [[DropBase:Contact|Martin Fischlechner]]


<br>
<br>
Line 24: Line 25:




=Downloads=
=Generic Designs=


i.  10 μM: [[Media:10um_2_inlets.png|png]], [[Media:10um_2_inlets.dxf|dxf]], [[Media:10um_2_inlets.dwg|dwg]] <br>
<ol style="list-style-type: lower-roman;">
ii.  20 μM: [[Media:20um_2_inlets.png|png]], [[Media:20um_2_inlets.dxf|dxf]], [[Media:20um_2_inlets.dwg|dwg]] <br>
<li> 10 μM: [[Media:10um_4_inlets.png|png]], [[Media:10um_4_inlets.dxf|dxf]], [[Media:10um_4_inlets.dwg|dwg]] <br></li>
iii. 30 μM: [[Media:30um_2_inlets.png|png]], [[Media:30um_2_inlets.dxf|dxf]], [[Media:30um_2_inlets.dwg|dwg]] <br>
<li> 20 μM: [[Media:20um_4_inlets.png|png]], [[Media:20um_4_inlets.dxf|dxf]], [[Media:20um_4_inlets.dwg|dwg]] <br></li>
iv. 40 μM: [[Media:40um_2_inlets.png|png]], [[Media:40um_2_inlets.dxf|dxf]], [[Media:40um_2_inlets.dwg|dwg]]
<li> 30 μM: [[Media:30um_4_inlets.png|png]], [[Media:30um_4_inlets.dxf|dxf]], [[Media:30um_4_inlets.dwg|dwg]] <br></li>
<li> 40 μM: [[Media:40um_4_inlets.png|png]], [[Media:40um_4_inlets.dxf|dxf]], [[Media:40um_4_inlets.dwg|dwg]] <br></li>
<li> 50 μM: [[Media:50um_4_inlets.png|png]], [[Media:50um_4_inlets.dxf|dxf]], [[Media:50um_4_inlets.dwg|dwg]] <br></li>
<li> 100 μM: [[Media:100um_4_inlets.png|png]], [[Media:100um_4_inlets.dxf|dxf]], [[Media:100um_4_inlets.dwg|dwg]] </li></ol>


<br>


<br>
=Published Designs=
<br>
<br>



Latest revision as of 06:48, 21 June 2021






Home        Devices        Contact       



Overview

Description

• Triple aqueous inlet flow-focusing junction
• the example shown has a 10 μm wide junction, although templates for a variety of different junction sizes are available to download

Reference

Devenish SRA, Kaltenbach M, Fischlechner M, Hollfelder F, Droplets as Reaction Compartments for Nanotechnology in Protein Nanotechnology, Edited by Gerrard J, Humana Press; 2013.

Submitted by: Martin Fischlechner




Generic Designs

  1. 10 μM: png, dxf, dwg
  2. 20 μM: png, dxf, dwg
  3. 30 μM: png, dxf, dwg
  4. 40 μM: png, dxf, dwg
  5. 50 μM: png, dxf, dwg
  6. 100 μM: png, dxf, dwg


Published Designs


Usage Notes

Please enter any comments that other users may find useful below this note (such as flow rates that worked well for particular oil/aqueous phases). When providing usage notes please provide as much detail as useful. We would request that you 'sign' any comments with your initials.