Biomod/2011/UTAustin/Hook'em Hybridizers:Methods: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
No edit summary
No edit summary
Line 17: Line 17:
*# '''Ware gloves at all time in the lab (never in the office).'''  There are two reasons for doing this.  First, it protects you from toxic reagents that had been accidentally spilled on the surface of benches, containers, equipments, keyboards of the computers that control equipments, etc.  Second, it projects the reagents from contamination (especially RNase) that's carried on your skin.
*# '''Ware gloves at all time in the lab (never in the office).'''  There are two reasons for doing this.  First, it protects you from toxic reagents that had been accidentally spilled on the surface of benches, containers, equipments, keyboards of the computers that control equipments, etc.  Second, it projects the reagents from contamination (especially RNase) that's carried on your skin.
*# '''Isolate glove-free zones where you want to touch things with bare hands.'''  You may want to designate an island on your bench to put lab notebooks, laptops, or other objects that you might touch outside the lab.  Remember to take off gloves when you touch things in this island.  You might as well establish a habit of where on drawers, doors, freezer handles, etc. you touch with gloves, and where without gloves.  Ideally, the set of objects you touch with gloves and that without gloves should not intersect.
*# '''Isolate glove-free zones where you want to touch things with bare hands.'''  You may want to designate an island on your bench to put lab notebooks, laptops, or other objects that you might touch outside the lab.  Remember to take off gloves when you touch things in this island.  You might as well establish a habit of where on drawers, doors, freezer handles, etc. you touch with gloves, and where without gloves.  Ideally, the set of objects you touch with gloves and that without gloves should not intersect.
*# '''Label ALL reagent containers.'''  Enough information should be written on the label so you, and other people, know who made it, when and how it was made, what special attention should be taken, etc.  Some general and reagent-specific information that should be written is detailed below:
*# '''Label ALL reagent containers.'''  Enough information should be written on the label so you, and other people, know who made it, when and how it was made, what special attention should be taken, etc.  We label the word '''"BIOMOD"''' on everything we use to separate our stuffs from other Ellington Lab stuffs.  You initial should follow "BIOMOD", e.g. '''"BIOMOD-XY"''' or '''"BIOMOD(XY)"'''.  Let's standardize our naming convention:  If the label is '''"BIOMOX(XY)"''', it means the person whose initial is XY made this reagent for BIOMOD team; everybody in the team can use it; and if this reagent runs low we should notify this XY person.  If the label is '''"BIOMOD-XY"''', it means only this XY person can use this reagent.
<br>Some general and reagent-specific information that should be written is detailed below:
*## '''Name and concentration of the reagent (mandatory for all reagents).'''  Both standard (e.g. IUPAC) nomenclature and common name, both full name and acronym are acceptable, as long as it is '''unambiguous'''.
*## '''Name and concentration of the reagent (mandatory for all reagents).'''  Both standard (e.g. IUPAC) nomenclature and common name, both full name and acronym are acceptable, as long as it is '''unambiguous'''.
*## '''Your initial (mandatory for all reagents)'''
*## '''Your initial (mandatory for all reagents)'''

Revision as of 16:42, 6 June 2011

Home        Rationale        Stimulation        Methods        Results        People        Contact       


  • UT-BIOMOD lab rules
    1. Ware gloves at all time in the lab (never in the office). There are two reasons for doing this. First, it protects you from toxic reagents that had been accidentally spilled on the surface of benches, containers, equipments, keyboards of the computers that control equipments, etc. Second, it projects the reagents from contamination (especially RNase) that's carried on your skin.
    2. Isolate glove-free zones where you want to touch things with bare hands. You may want to designate an island on your bench to put lab notebooks, laptops, or other objects that you might touch outside the lab. Remember to take off gloves when you touch things in this island. You might as well establish a habit of where on drawers, doors, freezer handles, etc. you touch with gloves, and where without gloves. Ideally, the set of objects you touch with gloves and that without gloves should not intersect.
    3. Label ALL reagent containers. Enough information should be written on the label so you, and other people, know who made it, when and how it was made, what special attention should be taken, etc. We label the word "BIOMOD" on everything we use to separate our stuffs from other Ellington Lab stuffs. You initial should follow "BIOMOD", e.g. "BIOMOD-XY" or "BIOMOD(XY)". Let's standardize our naming convention: If the label is "BIOMOX(XY)", it means the person whose initial is XY made this reagent for BIOMOD team; everybody in the team can use it; and if this reagent runs low we should notify this XY person. If the label is "BIOMOD-XY", it means only this XY person can use this reagent.


Some general and reagent-specific information that should be written is detailed below:

      1. Name and concentration of the reagent (mandatory for all reagents). Both standard (e.g. IUPAC) nomenclature and common name, both full name and acronym are acceptable, as long as it is unambiguous.
      2. Your initial (mandatory for all reagents)
      3. The date on which the reagent was made (mandatory for all reagents). This together with the initial allows one to trace back how the reagent was made on the lab notebook of the person who made it.
      4. Sterilization method (mandatory for stock solutions with > 10 mL volume). Typical sterilization methods include autoclave and filter. Preferably, you should add the parameter of the sterilization, e.g. temperature and duration of autoclave (typically 121 oC for 20 min) and pore size of the filter (typically 0.22 or 0.45 micron).
      5. Preparation method and purity (highly recommended for small-volume reagents prepared in the lab, including DNA strands and complexes). This is typically 'gel-purified', 'native gel-purified', 'HPLC purified'. You can also use your own acronym system as long as you can read it and keep the system consistent. This is sometimes important because the writing area on tubes is usually small.
  • UT-BIOMOD Experimental tips
    1. How to choose among different types of water.
    2. How to choose among different types of gel.
  • UT-BIOMOD protocols
    1. 10X TBE (200ml)
      (Note:Make it fresh now b/c it precipitates, this is enough for both the 20% and dilution)
      21.6 grams Tris base
      11 grams Boric Acid
      8mL 0.5M EDTA
      adjust to 200mL w/ H20
    2. 20% Acrylamide with 7M Urea in 1x TBE (1L)
      Add one 500mL bottle of 40% 19:1 Tris
      Add 100mL of 10X TBE
      Add 420grams Urea
      mix with stirbar until dissolved (~2hrs)
      adjust to 1L H20
      Filtered with .45uM
    3. Dilution Buffer with 7M Urea in 1x TBE(1L)
      Add 100mL of 10X TBE
      Add 420grams Urea
      mix with stirbar until dissolved (~2hrs)
      adjust to 1L H20
      Filtered with .45uM