==Entry title==
==Size exclusion filter purification==
* Insert content here...
 
===Folded samples BM_2_1565 (23.8.2011) and BM_2_5Dh3ml (23.8.2011) were filtered in the following manner===
 
 
  - 50 µl from both samples were mixed and put into a Amicon filter
  - 400 µl buffer added
  - spinned for 5 minutes at 14000 rcf
  - 400 µl buffer added
  - spinned for 5 minutes at 14000 rcf
  - 400 µl buffer added
  - spinned for 5 minutes at 14000 rcf
  - turned the filter and sinned the purified sample into a new Epi for 2 minutes at 1000 rcf
  - 1 x and 2 x filtered buffer filled into separate  Epi (the buffer, which came through the filter; if purification with spin columns works, this should only contain staples)
  - 3 x timed filtered buffer discarded
 
===Ran a 50 ml 2% Agarose-Gel with EtBr===
 
  - 1kb ladder
  - p7560
  - BM_2_1565
  - BM_2_5Dh3ml
  - 1x filtered buffer
  - 2x filtered buffer
 
Ask Marty about buffer and exact procedure!!!
 





Revision as of 02:33, 6 September 2011

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Size exclusion filter purification

Folded samples BM_2_1565 (23.8.2011) and BM_2_5Dh3ml (23.8.2011) were filtered in the following manner

  - 50 µl from both samples were mixed and put into a Amicon filter
  - 400 µl buffer added
  - spinned for 5 minutes at 14000 rcf
  - 400 µl buffer added
  - spinned for 5 minutes at 14000 rcf
  - 400 µl buffer added
  - spinned for 5 minutes at 14000 rcf
  - turned the filter and sinned the purified sample into a new Epi for 2 minutes at 1000 rcf
  - 1 x and 2 x filtered buffer filled into separate  Epi (the buffer, which came through the filter; if purification with spin columns works, this should only contain staples)
  - 3 x timed filtered buffer discarded

Ran a 50 ml 2% Agarose-Gel with EtBr

  - 1kb ladder