Microarray technology is the principle service offered by the MIT BioMicro Center. BMC has extensive experience with several different types of samples and platforms. Microarray labeling and hybridization are typically preformed by BioMicro Center technicians, however our scanners, hybridization ovens and wash stations are available by request.  
The MIT BioMicro Center retains minimal support for Agilent and Affymetrix Microarrays. Assisted microarray serves are no longer available. The Agilent oven and microarray scanner are available to users who prepare their own arrays and remains under service contract. Our Affymetrix instrumentation is available for use at user's risk.


== BioMicro Center Services ==
Please note that the BioMicro Center no longer supports printing of microarrays in house. Custom oligonuclotide arrays are available from Agilent at the same cost as their commercial arrays using their [http://www.chem.agilent.com/en-US/products/instruments/dnamicroarrays/pages/gp50660.aspx eArray system] (we can [[BioMicroCenter:Computing#BioInformatics_Services|help you]] through the process of designing arrays). For anyone requiring microarray printing, we encourage you to contact [http://jura.wi.mit.edu/genomecorewiki/index.php/Tom_Volkert Tom Volkert at the Whitehead Institute CGT].
We are currently set up to primarily handle expression analysis. Our service includes:


* Evaluation of sample quality using the [[BioMicroCenter:2100BioAnalyzer|Agilent BioAnalyzer 2100]]
== MICROARRAY SCANNER ==
* Sample labeling and clean up.
{| align=left
* Array Hybridization.
  |- style="vertical-align: top;"
* Data extraction and normalization.
  |style="width: 300px;"|
 
  {| class="wikitable" border=1
We also have discounts with different vendors and can help you purchase your arrays.
  ! Instrument || Agilent DNA scanner
<br>
  |-
=== SAMPLE TYPES ===
  | TYPE || WALKUP - MIT only
The BioMicro Center has extensive experience handling samples for expression analysis.
  |-
 
  | UNIT || Per Slide
{|border=1
  |-
  |-
  | FORMAT || Glass slides
  ! Eukaryote
  |-
  ! Min.RNA
  | SIGNUP || [https://mit.ilabsolutions.com/equipment/show/261696/?tab=schedule ilabs]
! Min.Vol.
  |-
! Notes
  | NEW USERS ||  New users should request training by emailing biomicro@mit.edu
|-
  |-
| Prokaryote
  | DONATED BY || Dr. Stephen Bell. <BR> Upgrade by Dept of Biology.
| 1 μg
  |}
| 6 μL
  |
| labeling using [http://www.ambion.com/catalog/ProdGrp.html?fkProdGrp=339 Ambion] for Affy arrays
The Agilent scanner provides red/green scanning of glass slides at 2μm resolution. While built for Agilent arrays, the scanner is capable of handling a broad spectrum of different printed arrays. Agilent Feature Extractor provides basic data analysis as well as quality control. We are currently running Feature extractor version 10.5. Gasket slides and ozone protection covers designed for Agilent arrays are available in the lab.
|-
| 3' Array (std)
| 50ng / 100pg
| 6 μL
  | labeling using NuGEN for Affy arrays.  
|-  
| Exon Array
| 50ng / 100pg
| 6 μL
  | labeling using NuGEN for Affy arrays
  |-
| small RNA
| N/A
| N/A
|BMC recommends the use of multiplexed [[BioMicroCenter:Sequencing|Illumina sequencing]] for small RNA samples
|}
|}
<br>
=== SAMPLE SUBMISSION ===
We encourage researchers to contact us several days in advance of sample submission to allow us lead time to purchase any specialized Affymetrix or Agilent arrays. While we keep a few arrays in stock, most arrays are ordered on an as needed basis. A list of some of the available arrays and their prices can be found [[Media:Affy_Arrays_081218.pdf| in this file]]. Information about Affymetrix arrays is available at http://www.affymetrix.com/products_services/index.affx
All submissions must be accompanied by a [[BioMicroCenter:Forms#Downloads | Affymetrix Submission Form]].
<br>
=== TURN AROUND ===
The BioMicro Center will turn around your samples as quickly as possible. We are currently exploring methods of increasing our sample throughput to reduce turn around time. Currently the average turn around time is currently 2-3 weeks.
<br>
=== NON-MIT USERS ===
Please contact [[BioMicroCenter:People|Manlin Luo]] to arrange a drop off date and time. Samples on dry ice and chips at room temperature with a completed order form are shipped by overnight delivery to:
  MIT BioMicro Center
  Attention: Manlin Luo
  31 Ames Street, Building 68-316
  Cambridge, MA 02139
<br>
=== [[BioMicroCenter:Pricing|PRICES]] ===
Please note that processing prices '''do not''' include the cost of the array.  In order to be sure we have arrays on hand, we encourage users to contact us several days in advance of submitting samples.
{| border=1  style="text-align:center"
! ITEM
! style="width:100px"|[[CoreDeps|CORE LAB]]
! style="width:100px"| MIT
! style="width:100px"| NON-MIT
! style="width:100px"| unit
! style="width:100px"| Notes
|-
| colspan="7" | '''AFFYMETRIX PROCESSING'''
|-
| Affy 3' Processing || $260 || $430 || $645 || per array || Using NuGEN sample labeling kit
|- 
| Affy Exon Processing || $320 || $535 || $800 || per array || Using NuGEN sample labeling kit
|-
| Affy Prokaryote || $250 || $430 || $645 || per array || Using Ambion sample labeling kit
|-
| Fluidics Station and Scan || $130 ||$130 || N/A || per array || Users must be trained, please coordinate with Manlin
|-
| colspan="7" | '''AGILENT PROCESSING'''
|-
| Eukaryote Expression || $270 || $430 || $645 || per array || Includes both Cy5 and Cy3
|-
| aCGH || $250 || $430 || $645 || per array || Includes both Cy5 and Cy3
|-
| Scanning Only || $50 || Free || N/A || per slide || Priced per glass slide, Increase reflects service contract cost.
|}
<br>
Common Affymetrix Arrays (some in stock):
* Human U133 Plus 2.0 / Mouse 430 2.0 - '''$400'''
* Human U133A 2.0 / Mouse 430A 2.0 - '''$250'''
* Human / Mouse Exon 1.0 ST - '''$400'''
* Yeast 2.0 - '''$175'''
Full Price List: [[Media:Affy_Arrays_081218.pdf| Affymetrix Prices]]
== Platforms ==
The BioMicro Center currently processes two types of Arrays:
* [http://www.affymetrix.com AFFYMETRIX] - Affymetrix offers one color arrays for a variety of assays including expression, ChIP-chip, and SNP analysis. We routinely use Affymtrix arrays for the quantification of 3' ends and whole transcripts (exon arrays) from both eukaryotes and prokaryotes. The BioMicro Center has a hybridization oven, two 450 fluidics devices and a 7G scanner for handling Affymetrix arrays. As part of our effort to control costs, the BioMicro Center is part of the Core Lab program, which lowers our annual maintenance contract and allows us to maintain a number of standard array types in stock.
* [http://www.agilent.com AGILENT] - Agilent offers two-color arrays for a variety of assays including gene expression, ChIP-chip, miRNA hybridization, and CGH. The MIT BioMicro Center hosts a hybridization oven and a high-throughput Agilent Microarray Scanner donated by the Bell lab. We do not currently maintain a stock of Agilent arrays but do have a significant discount on the purchase of arrays.
Please note that the BioMicro Center no longer supports self printed arrays. Custom oligonuclotide arrays are available from Agilent at the same cost as their commercial arrays using their [http://www.chem.agilent.com/en-US/products/instruments/dnamicroarrays/pages/gp50660.aspx eArray system] (we can [[BioMicroCenter:Computing#BioInformatics_Services|help you]] through the process of designing arrays). For anyone requiring self printed arrays, we encourage you to contact [http://jura.wi.mit.edu/genomecorewiki/index.php/Tom_Volkert Tom Volkert at the Whitehead Institute CGT].
== Technology Updates ==
=== Labeling Kits ===
[[Image:BMC_NugenKit.png|right]]
Affymetrix is retiring their old 3' Array kits in September 2009. In response, BMC has been evaluating new technologies. The newer kits are faster and require less starting material. We have selected the NuGEN technology as the primary labeling method we will be using going forward for eukaryotic arrays because of their ease and the modularity of their system that allows us to combine the processing of Affymetrix 3', Affymetrix Exon, and Agilent arrays. Information on the evaluation can be found '''[[BioMicroCenter:3primeIVT|HERE]].'''. We DO NOT RECOMMEND mixing labeling types within an experiment as we have observed large differences between the absolute intensities of signals between labeling methods. Arrays can still be hybridized using the Affymetrix 3'IVT, Affymetrix Exon and old Affymetrix 3' array by request (please ask for pricing).
We have also switched our prokaryotic labeling system from the Affymetrix system to one developed by [http://www.ambion.com/catalog/ProdGrp.html?fkProdGrp=339 Ambion]. The Ambion system requires significantly less input RNA and has a more streamlined protocol. The Affymetrix labeling system is still available by request.
=== Small Cell Numbers ===
NuGEN has recently developed kits that allow the analysis of very [http://www.nugeninc.com/nugen/index.cfm/products/amplification-systems/wt-ovation-pico/ small amounts of purified RNA (100pg)] or even [http://www.nugeninc.com/nugen/index.cfm/products/amplification-systems/wt-ovation-one-direct/ single cells]. Please contact [[BioMicroCenter:People|Stuart Levine]] if you are interested in trying out these technologies.
== Analysis and Data Retrieval ==
=== Affymetrix Data Analysis ===
BioMicro Center will perform the initial data extraction of your samples using Affymetrix GCOS V.1.4. Affymetrix data is scaled to a average intensity of 500 per chip. Six files for each sample will be provided to the user:
* .exp: Experiment information file
* .dat: The image of the scanned probe array.
* .cel: Cell Intensity File derived from  .dat file.
* .chp: Output file generated from the analysis of a probe array.
* .rpt: Report File generated.
* .txt: Text File is the same information as the .chp file in text format.
Additional data analysis help is available on a case by case basis. Please contact [[BioMicroCenter:People|Stuart Levine]] if you need additional help with your analysis.
=== Agilent Data Analysis ===
Agilent Scanner is available to members of the MIT Community without charge. If you are the first time user, contact [[BioMicroCenter:People|Stephen Goldman]] to set up a bionet account for your data storage. For questions about equipment, contact [[BioMicroCenter:People|Manlin Luo]]
After you have completed your scan, please make sure to sign the scanner record form, which is  near the equipment and to remove your files from the computer. CD-Rs are available if needed.
=== Data Transfer ===
You will be notified by email that your data is ready. At that time please pick up any leftover samples and arrays belonging to you. Samples will be held at the facility at -80C for 60 days after your data is generated.
The data will be placed on our server for you the download.
Downloading Applications
Windows Application
*There is a Windows applications client called SSH Secure Shell available at :
*http://biomicro-bioanalyzer.mit.edu
*Instructions to use the application can be found [[ Instructions to use SSH ]].
Macintosh Application
*There is a Macintosh client called Fetch 5.3.for Macintosh.
*It can found http://ist.mit.edu/ 
*Select software :  File transfer – Macintosh
*Direction for installing and using Fetch are located here:
*http://ist.mit.edu/services/software/fetch/53
Accessing the server.
Your user name and password will be included in the email. To obtain your data, enter the following in your client:
  Host:      bmc-150.mit.edu
  user:      provided in email     
  Password:  provided in email
Please contact [[BioMicroCenter:People|Stephen Goldman]] if you have difficulty obtaining your data.

Latest revision as of 05:34, 22 October 2018

HOME -- SEQUENCING -- LIBRARY PREP -- HIGH-THROUGHPUT -- COMPUTING -- OTHER TECHNOLOGY

The MIT BioMicro Center retains minimal support for Agilent and Affymetrix Microarrays. Assisted microarray serves are no longer available. The Agilent oven and microarray scanner are available to users who prepare their own arrays and remains under service contract. Our Affymetrix instrumentation is available for use at user's risk.

Please note that the BioMicro Center no longer supports printing of microarrays in house. Custom oligonuclotide arrays are available from Agilent at the same cost as their commercial arrays using their eArray system (we can help you through the process of designing arrays). For anyone requiring microarray printing, we encourage you to contact Tom Volkert at the Whitehead Institute CGT.

MICROARRAY SCANNER

Instrument Agilent DNA scanner
TYPE WALKUP - MIT only
UNIT Per Slide
FORMAT Glass slides
SIGNUP ilabs
NEW USERS New users should request training by emailing biomicro@mit.edu
DONATED BY Dr. Stephen Bell.
Upgrade by Dept of Biology.

The Agilent scanner provides red/green scanning of glass slides at 2μm resolution. While built for Agilent arrays, the scanner is capable of handling a broad spectrum of different printed arrays. Agilent Feature Extractor provides basic data analysis as well as quality control. We are currently running Feature extractor version 10.5. Gasket slides and ozone protection covers designed for Agilent arrays are available in the lab.