BioMicroCenter:DNA HTL: Difference between revisions
(New page: {{BioMicroCenter}} The BioMicro Center offers high-throuhgput DNA library preparation for NexteraXT samples and for metagenomics/amplicon generation. High-throughput library generation is...) |
|||
Line 31: | Line 31: | ||
|colspan=2| * For short PCR fragments, <u>lower</u> concentrations are required. Please speak with BMC staff for amplicons. | |colspan=2| * For short PCR fragments, <u>lower</u> concentrations are required. Please speak with BMC staff for amplicons. | ||
|} | |} | ||
<BR><BR> | |||
== 16S / Amplicon Sequencing == | == 16S / Amplicon Sequencing == |
Revision as of 04:55, 18 August 2016
HOME -- | SEQUENCING -- | LIBRARY PREP -- | HIGH-THROUGHPUT -- | COMPUTING -- | OTHER TECHNOLOGY |
The BioMicro Center offers high-throuhgput DNA library preparation for NexteraXT samples and for metagenomics/amplicon generation. High-throughput library generation is different from standard library preparation in a couple key ways. First, with dozens of samples to prepare, small numbers of samples may fail and the cost of reprepping those samples is NOT included in the quoted cost. For some experiments, repreps can be done by hand, but at a higher rate. Second, we are focused far more on reducing price than for standard library preparation, so some "routine services" - such as quality control or arraying of samples - is not built in.
High-Throughput Nextera XT
To minimize library prep costs for standard Illumina libraries, we have automated Illumina NexteraXT on our Tecan EVO150s. Libraries will be built to include variable i5 and i7 indexes based on the grid so dual indexing is required during sequencing of these libraries. For more information about how Nextera works, please check out the standard Nextera library preparation section of standard DNA library prep.
Plate setup | |
---|---|
Batch Size | 16 |
Sample Layout | Columns from left |
Volume | >7ul |
Concentration | 0.2ng/ul* |
Buffer | H2O or 10mM Tris 8.0. no organics! |
Plate | Axygen 96well (CAT#) |
Additional services available can be added if samples are not submitted as above |
|
* For short PCR fragments, lower concentrations are required. Please speak with BMC staff for amplicons. |
16S / Amplicon Sequencing
Plate setup | |
---|---|
Batch Size | 48 |
Sample Layout | Columns from left |
Volume | >5ul |
Concentration | Iniital qPCR for target has Ct < 20 |
Buffer | H2O or 10mM Tris 8.0. no organics! |
Plate | Axygen 96well (CAT#) |
Additional services available can be added if samples are not submitted as above |
|