BioMicroCenter:ChIP Seq: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
Line 50: Line 50:
|align="right"| $1,200
|align="right"| $1,200
  |align="center"| per lane
  |align="center"| per lane
  | Includes quality control (RT-PCR or BioAnalyzer, sequencing, genome alignment and data storage of Firecrest files for 2 yrs.  
  | Includes quality control (RT-PCR and BioAnalyzer), sequencing, genome alignment and data storage of Firecrest files for 2 yrs.  
  |-
  |-
  | Sample Multiplexing
  | Sample Multiplexing

Revision as of 16:51, 31 March 2010

HOME -- SEQUENCING -- LIBRARY PREP -- HIGH-THROUGHPUT -- COMPUTING -- OTHER TECHNOLOGY
Marson A, et al. Cell 2008

ChIP-seq

Chromatin Immunoprecipitation Sequencing (ChIP-Seq) combines ChIP with DNA sequencing, allowing researchers to identify the binding sites of DNA-associated proteins. It can be used as a more cost effective and higher quality alternative to whole genome microarray hybridization. http://illumina.com/downloads/ChIP-Seq_DataSheet.pdf

Sample Submission Guidelines

Users are required to prepare their own libraries for sequencing by following the corresponding Illumina Protocols. If this is a service that you would like the BMC to perform in the future please visit the Ideas page. Illumina ChIP-seq sample preparation kits can be purchased directly from Illumina or through the BioMicro Center for $2,300.00 plus shipping costs (10 sample preps per kit). To request an order or for more information please contact Ali Perrotta

Samples which are ready for sequencing should be gel-purified according to your protocol, and provided as at least 5uL of solution at a concentration of at least 10nM in EB/Tween 0.1%. To calculate your sample’s molar concentration, you must know the average length of your product.

When submitting a sample you must supply the BMC with the molar concentration, average length, and species of origin of all samples.

We encourage all those submitting samples to allow us to run QC to obtain/confirm concentration information. For more information on our QC methods please see the Sequencing Quality Control page.

Samples generated using standard kits with Illumina PCR primers can be submitted without sequencing primers. Custom sample preparations using customized PCR primer sequences should be provided along with a complementary sequencing primer.

Sample Submission Forms

Data

Images acquired from the Illumina sequencer are processed through the bundled Illumina analysis pipeline to identify the sequence and quality score for each base. The data can then be aligned to a reference genome, if requested, using an interactive ELAND algorithm. An in-depth QC report of the data is included in the package.

Output Files:

  • sequence.txt
  • eland_query.txt
  • eland_result.txt
  • realign.txt

More information about the output files can be found on the Illumina Pipeline page.

Turnaround Time

Each Genome Analyzer processes 8 samples per run, or 7 samples plus a control. The control is typically used to improve sequence quality. Full flowcells can be run usually within two weeks of submission. Partial submissions of less than eight samples (or 7 with control) are put into a project queue, where they join existing samples or await others before processing. Wait times for partial submissions vary depending on demand from other users. Once the run has begun approximately six days are required for clustering, sequencing, and data analysis for a 36 base pair read. The process requires approximately 5 days for a 25 base pair read.

Pricing

Illumina sequencing is currently available only for labs associated with the BioMicro Center Core departments.

ILLUMINA SEQUENCING CORE LAB/MIT Non-MIT unit Notes
Single End (36nt) $860 $1,200 per lane Includes quality control (RT-PCR and BioAnalyzer), sequencing, genome alignment and data storage of Firecrest files for 2 yrs.
Sample Multiplexing $50 $300 per 10 samples Combined over the whole order. Only applies to samples combined by BCM technicians.
Add'l Repriming $300 $400 per flow cell Uses 6nt. Cost is divided by number of lanes requiring repriming. Repriming is required for standard Illumina multiplexing.



.

ChIP Seq Literature

<biblio>

  1. Paper1 pmid=18692474 <!-mirna 2008->
  1. Paper2 pmid=17558387