#*The amount of time that one waits is dependent upon what you are growing the cells to do.  To [[Miniprep|miniprep]] plasmid DNA, an overnight culture is sufficient.  However, when doing measurements of protein levels, one should take care to take readings at the same cell culture density each time.
#*The amount of time that one waits is dependent upon what you are growing the cells to do.  To [[Miniprep|miniprep]] plasmid DNA, an overnight culture is sufficient.  However, when doing measurements of protein levels, one should take care to take readings at the same cell culture density each time.
[[Category:E.Coli Protocol]]

Revision as of 16:47, 29 July 2005

Materials

  • Glass culture tubes with metal caps and labels
  • Growth medium, from media room or customized
  • Glass pipette tubes
  • Parafilm

Equipment

  • Vortexer
  • Fireboy or Bunsen burner
  • Motorized pipette
  • Micropipettes and sterile tips

Procedure

For a typical liquid culture, use 5 ml of appropriate medium. The amount in each tube does not have to be exact if you are just trying to culture cells for their precious DNA.

  1. Streak an agar plate from glyerol stock. Incubate plates until colonies grow.
    • Most incubations with E. coli take place at 37°C. Often bacteria with temperature sensitive mutations need to be grown at 30° instead.
    • The reason you need to streak plates is to be certain that you are starting from a single clonal population of cells. In this case, colonies that are picked are assumed to arise from a single cell dividing to form the colony.
    • Agar plates are just the standard. There are many different plating media that can be used (i.e., blood agar).
  2. Take your plates from the warm room. Take an aliquot of the antibiotic(s), if needed, from the freezer, and set it on the bench to thaw.
  3. Flame a glass pipette, open the bottle of medium and flame the mouth, measure out the amount you need to fill your tubes, flame the cap and recap the bottle as quickly as possible.
  4. Remove the tube cap, flame the top of the culture tube, pipette in 5 ml, flame the top of the tube, and cap it.
  5. Pick up one colony by tapping a small (0.1 μl) pipette tip (held on a pipette) on the surface of the plate. Uncap a tube, flame the top, eject the tip into the tube, flame, cap. You can also use a sterile toothpick for transfer, but this method gives a clear indication of which tubes have been inoculated.
    • Often people use just a sterile metal loop (sterile by flaming) to place the colony in the tube. This is because flaming assures the sterility of the loop, whereas disposables such as pipette tips and toothpicks can be contaminated, and cannot be flamed on the spot.
  6. Pipette the desired amount of antibiotic into each tube along the wall. Do not put the non-sterile part of the pipette inside the tube and use a new tip for each tube.
  7. Vortex each tube for 1-2 seconds to mix well.
  8. Take the tubes to incubate. Turn the rotating rack off using the dial to decrease the speed. Do not use the switch because the motion is too abrupt. Add your tubes in a balanced layout. If you have an odd number, there are extra tubes for balance in the box on the floor next to the machine. Turn the rotating back on to 7. Do not forget to turn the rack back on.
    • Incubation once again is often at 37°C in the temperature controlled room.
  9. Wait overnight or until your cells have reached the desired concentration.
    • The amount of time that one waits is dependent upon what you are growing the cells to do. To miniprep plasmid DNA, an overnight culture is sufficient. However, when doing measurements of protein levels, one should take care to take readings at the same cell culture density each time.