BME100 s2016:Group13 W1030AM L6: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
Line 81: Line 81:
''' Consumables Kit'''
''' Consumables Kit'''


[[Image:BME100_Kit.PNG|600px]]
[[Image:BME100_Kit.PNG|alttext]]


Our consumables kit will include:<br>
Our consumables kit will include:<br>

Revision as of 21:23, 25 April 2016

BME 100 Spring 2016 Home
People
Lab Write-Up 1 | Lab Write-Up 2 | Lab Write-Up 3
Lab Write-Up 4 | Lab Write-Up 5 | Lab Write-Up 6
Course Logistics For Instructors
Photos
Wiki Editing Help

OUR COMPANY

Name: Brian
Name: Najila
Name: Andrej
Name: Bradley
Name: Shantelle
Name: Slade


LAB 6 WRITE-UP

Bayesian Statistics

Overview of the Original Diagnosis System

In BME 100, 17 groups of 4-6 students per group each diagnosed two patients resulting in 34 patients total. The patients were screened for the SNP strand of DNA which was the gene that coded for non-Hodgkin Lymphoma. In order to screen the patients for the SNP gene disease marker the PCR machine replicated the disease forward and reverse DNA strand. After the experiment was completed in the PCR machine the PCR products from each test tube was added into its respected 500 micro-liter buffer solution. The image J portion of the lab consisted of a Calf thymus DNA solution of 0, 0.25, 0.5, 1, 2, and 5 micrograms per milliliter concentration. Also the eight test tubes of the PCR reaction which consisted of the positive, negative, three samples from patient one, and three samples form patient two. Eighty micro-liters of the DNA solution was pipetted onto a glass sheet, then 80 micro-liters of SYBR Green I was pipetted onto the bubble of PCR reaction in order to bind to the SNP genes and glow when a light is shined through the bubble forming a 160 micro-liter bubble. The phone camera was then placed 4cm away from the bubble and three pictures of each bubble formed with the pipette were taken in order to ensure a quality picture was taken, resulting in 42 photos total. After each pipetting the old tip was disposed of and a new tip was put on in order to prevent cross contamination. Also the glass plate was moved over in order to get a new gap in order to prevent cross contamination. This was important because both processes were used to prevent inaccurate results. However the main problem with this lab was with keeping the SYBR Green I in the dark when using it, which was an important task to do because SYBR Green I was less reactive the longer it was exposed to light. Based off the final results: .889 frequency for positive results, 0.875 frequency for negative results, 0.500 frequency for positive results correlated with the doctors diagnosis, and 0.889 frequency for negative results that correlated with the doctors diagnosis.


What Bayes Statistics Imply about This Diagnostic Approach


For Calculation one the question, what is the probability of a pos final test given a pos PCR? was analysed. P(A) means the probability of a pos final test, which resulted in a frequency of 0.380. P(B) means the probability of a positive PCR test, which resulted in 0.380. P(B/A) means the probability of a pos PCR test given a pos final test, which resulted in 0.830. P(A/B) means the probability of a pos final test resulting in a pos PCR test, which resulted in 0.830 based off the Bayesian equation.

For Calculation two the question, what is the probability that a patient will get a negative final test conclusion, given a negative PCR Reaction? was analysed. P(A) means the probability of a negative final result, which resulted in a frequency of 0.560. P(B) means the probability of a negative PCR reaction, which resulted in 0.580. P(B/A) means the probability that a neg PCR reaction will result in a negative final result, which resulted in a frequency of 0.880. P(A/B) means the probability that a patient with a negative final result will result in a negative PCR reaction, which resulted in a frequency of 0.840 based off Bayes formula.

For calculation three the question was, what is the probability that a patient develops the disease given a positive test? was analysed. The P(A) wants the frequency that people will develop the disease, which resulted in 0.28. The P(B) means the frequency of a positive test result, which resulted in 0.38. The P(B/A) means the probability given a positive test means that the patient will develop the disease. which resulted in 0.50. The P(A/B) means the probability that a positive test result will result in the person developing the disease, which resulted in 0.37 based off the Bayesian equation.

For Calculation four the question was, what is the probability of a person with no disease given a negative final test? P(A) means the probability of no disease, which resulted in 0.720. P(B) means the probability of a negative test, which resulted in a 0.56 frequency. P(B/A) means the probability of a negative test given that the patient does not have the disease, which resulted in a 0.6950. P(A/B) means the diagnoses of disease given a negative test result, which resulted in 1.14 based off the Bayesian equation. The three main source of error in this experiment were from not placing the camera in the same spot for each droplet causing the pixels to be inconsistent. The PCR machine might of not been closed all the way, it was hard to tell since it was a screw on lid. If the machine is not closed correctly then it could affect the temperature causing an incomplete PCR reaction resulting in faulty data. The third source of error is mainly human error that occurred with pipetting, there was a high possibility of cross contamination due to the necessity for every solution to be kept separate.

Intro to Computer-Aided Design

TinkerCAD



As a group we logged onto TinkerCAD and went through the process of learning how to use the program. While working with tinker cad we determined that solid works was a better choice for this project. This is because Solid works had more mobility involving mating positions and multi-layer constructions. Tinker cad in comparison is significantly more user friendly because it only needed basic tutorials to create simple structures, and the product looks prettier. Overall TinkerCAD is a great program but our group members were already proficient in Solid works. Consequently, we stopped the tutorial and completed the assignment on Solid works. Besides being biased towards Solid works we found that Solid works made the figures look cleaner.

Our Design



OpenPCR Improvement


This is an adapter piece to allow for a Rasberry Pi 2 to be added to the back of the OpenPCR case. For only a $40 increase in cost, this allows for a web server interface with the Arduino directly, so that the unit can be shared within a Local Area Network, much like an office print server. The goal is that this small increase in cost would allow for 1 $600 unit to be shared with everyone within the building at universities, drastically cutting down on the overall cost of the investment.

Fluorimeter Design


One of the biggest problems we found with the current Fluorimeter design was that our camera phone kept shaking. This led to our spots moving from image to image, which ultimately impacted the accuracy of our data. This simple attachment was designed to hold a camera in place so that it could be used remotely, eliminating this error.

Feature 1: Consumables

Consumables Kit

alttext

Our consumables kit will include:
-Pipettor
-Standard Sized Disposable Tips
-Pre-labeled Test Tubes
-PCR mix (DNA primer, DNA polymerase)
-SYBR Green Solution
-Buffer

Our plastic tubes will be pre-labeled and will fit in any plastic tray due to it's universal design. They will open and close with ease for the convenience of saving time and avoiding accidents. The disposable tips will be standard size and work with any pipettor. Our reagents ( SYBR Green Solution, Buffer) will be prepackaged in all the right measurements all in one container so that mixing will be no problem resulting in a quicker process.


Feature 2: Hardware - PCR Machine & Fluorimeter

Adjustments to flourimiter: We added a low power fixed view camera that can be set to take pictures at certain intervals when triggered, the camera is made to save the pictures to an SD card inserted in a data port in the back of the unit. Additionally the unit is equipped with a slide lid to prevent any outside light sources from effecting the results.

Adjustments to PCR unit: We added a separate auxiliary computing unit (raspberry pi) allowing the PCR unit to be activate and controlled through a server or outside computer station, additionally this will allow the end user to program PCR cycles, and be informed when cycles begin and end. The computing unit also allows data to be stored to a SD card unit.