BME100 f2014:Group33 L6: Difference between revisions
Line 68: | Line 68: | ||
*SYBR Green | *SYBR Green | ||
*dNTP | *dNTP | ||
*glass slides | |||
<br>The consumables consisted of tubes, the tips, a micropipettor, PCR mix, and primers, but how they were packaged could create a messy workplace. The micropipettor tips were nicely placed in an organized tray, but the tray itself had some design issues. Due to an open bottom and loose enclosure of the tips, they were easily knocked out of the holding tray. And a certain type of micropipettor was needed so that it could fit in the tubes. The package would sometimes include the wrong type of micropipettor that was needed, in order to, pump in the PCR mix and primers. In a real life experiment, this would be an easy cause for contamination. The tubes can easily be knocked over spilling the contents of the samples, which could mix up the data. Not having the right type of micropipettor that fits in the tube could also create a mess at the workbench in lab, if the tip of it gets stuck in a tube and force is used to try and get it out. The consumables will be packaged more closely together to ensure that there are no gaps when delivering the product. And the micropipettor will be inspected to make sure that it is in the correct size that will fit in the tube, in order to suck up the primer and PCR mix to combine them. The tubes will also be reinforced into the plastic tray with a plastic grip that makes sure that the samples made do no come out easily, when making the samples, but still come out with relative ease when the samples need to be moved and tested in the PCR machine. | <br>The consumables consisted of tubes, the tips, a micropipettor, PCR mix, and primers, but how they were packaged could create a messy workplace. The micropipettor tips were nicely placed in an organized tray, but the tray itself had some design issues. Due to an open bottom and loose enclosure of the tips, they were easily knocked out of the holding tray. And a certain type of micropipettor was needed so that it could fit in the tubes. The package would sometimes include the wrong type of micropipettor that was needed, in order to, pump in the PCR mix and primers. In a real life experiment, this would be an easy cause for contamination. The tubes can easily be knocked over spilling the contents of the samples, which could mix up the data. Not having the right type of micropipettor that fits in the tube could also create a mess at the workbench in lab, if the tip of it gets stuck in a tube and force is used to try and get it out. The consumables will be packaged more closely together to ensure that there are no gaps when delivering the product. And the micropipettor will be inspected to make sure that it is in the correct size that will fit in the tube, in order to suck up the primer and PCR mix to combine them. The tubes will also be reinforced into the plastic tray with a plastic grip that makes sure that the samples made do no come out easily, when making the samples, but still come out with relative ease when the samples need to be moved and tested in the PCR machine. | ||
Latest revision as of 23:57, 25 November 2014
BME 100 Fall 2014 | Home People Lab Write-Up 1 | Lab Write-Up 2 | Lab Write-Up 3 Lab Write-Up 4 | Lab Write-Up 5 | Lab Write-Up 6 Course Logistics For Instructors Photos Wiki Editing Help | ||||||
U-BEAMS
LAB 6 WRITE-UPBayesian StatisticsOverview of the Original Diagnosis System There were 34 groups in the BME 100 lab each testing 2 different patients, giving a total of 68 patients. Every team got DNA samples of two different patients to test for SNP. Every group tested about three controlled samples of both negative and positive. In order to analyze them, there was a PCR machine that did this and then used the ImageJ system that would give us a good analysis of the drops. This image program gave us a good reading for each sample and minimized the error with its measures. After analyzing everything with each group, we had to input the data on to a spread sheet that would allow all of the classroom to make a final analysis. This made it possible to ensure an accurate analysis, since each patients DNA was tested at least three times. This also made it easier to make sure the whole lab class was concurring with each other. As long as the trials were similar to each other the data was accurate concerning whether the patients were positive or negative. Since so many trials were done by multiple groups; the amount of human error was decreased along with any errors that could have resulted from the Open PCR machine or the ImageJ software. Three images were taken of each sample to ensure that accurate data could still be gathered even if one or two of the other pictures seemed blurry. Everyone had the same procedure for the set up of the Open PCR machine as well as a positive and negative control. For our group we had the same people who had taken the pictures rename the pictures according to the patient type and trial, this way we were sure that the pictures accurately reflected the data and also renamed them to reduce confusion. The final data that was gathered was as accurate as it could have been because it functioned like how a real lab would in real time. Sometimes results are inconclusive and there were also blank spaces where some data was not recorded. Everyone in the lab tried to reduce the amount of errors preformed in the lab and so the data that was taken from other teams was given the benefit of the doubt that there results were as stated.
Computer-Aided DesignTinkerCAD
Feature 1: Consumables KitWeaknesses in the Consumables
Feature 2: Hardware - PCR Machine & FluorimeterWeaknesses of the PCR Machine & Flourimeter
|