<!-- Instructions: Write a medium-length summary (~10 - 20 sentences) of how BME100 tested patients for the disease-associated SNP. Describe (A) the division of labor (e.g., 34 teams of 6 students each diagnosed 68 patients total...), (B) things that were done to prevent error, such as the number of replicates per patient, PCR controls, ImageJ calibration controls, and the number of drop images that were used for the ImageJ calculations (per unique PCR sample), and (C) the class's final data from the BME100_fa2014_PCRResults spreadsheet (successful conclusions, inconclusive results, blank data). -->
<!-- Instructions: Write a medium-length summary (~10 - 20 sentences) of how BME100 tested patients for the disease-associated SNP. Describe (A) the division of labor (e.g., 34 teams of 6 students each diagnosed 68 patients total...), (B) things that were done to prevent error, such as the number of replicates per patient, PCR controls, ImageJ calibration controls, and the number of drop images that were used for the ImageJ calculations (per unique PCR sample), and (C) the class's final data from the BME100_fa2014_PCRResults spreadsheet (successful conclusions, inconclusive results, blank data). -->


<!-- [Rough Draft] Each team of was designated ___ patients each doing their own pcr analysis to check for the disease-associated SNP. To prevent error over the diagnostics teams overlapped in patients being tested to create ___ replicates and previous labs were conducted on how to go about the diagnostic to give an understanding to each team on how to proceed to avoid some of the more common errors that could result from mishandling the materials given. -->
<!-- [Rough Draft] Each team of was designated 2 patients each doing their own pcr analysis to check for the disease-associated SNP. To prevent error over the diagnostics teams replicated the DNA results 3 times to reduce possible errors. Previous labs were conducted on how to go about the diagnostic to give an understanding to each team on how to proceed to avoid some of the more common errors that could result from mishandling the materials given. After each team finished testing for their individual patients, the results were complied into a single spreadsheet to give an overview of the results over the entire BME 100 class. If the results of the DNA test didn't give a strong indication one way or the other, the test was ruled inconclusive to avoid declaration of an incorrect test.-->





Revision as of 23:04, 25 November 2014

BME 100 Fall 2014 Home
People
Lab Write-Up 1 | Lab Write-Up 2 | Lab Write-Up 3
Lab Write-Up 4 | Lab Write-Up 5 | Lab Write-Up 6
Course Logistics For Instructors
Photos
Wiki Editing Help


OUR COMPANY

Name: Amanda Smith
Name: Blake Morrow
Name: Mitchell Durbin
Name: Julian Bertrandt
Name: Zied Alghamdi
Name: Gergey Mousa


Flourimitrix

LAB 6 WRITE-UP

Bayesian Statistics

Overview of the Original Diagnosis System


What Bayes Statistics Imply about This Diagnostic Approach


Calculations 1 and 2 were both close to 1.00 (100%). Having these calculations close to 1 imply that the reliability of the individual PCR replication for concluding that a person has the SNP disease or not is high. This shows that there is likely a correlation between a positive/negative final test conclusion and a positive/negative PCR reaction, respectively. This is essentially showing that there is a high probability of having a positive final test conclusion (A) given a positive PCR reaction (B), and vise verse, as shown with the high percentages of P(AB).

There were many sources of possible human or device error that could have occurred during the PCR & detection steps that could have affected the Bayes values in a negative way. The solutions in the PCR tubes may have not been precise, the PCR machine may not have taken the solutions to the proper cold and hot temperatures, the PCR machine may have not gone on for the precise time, the pictures taken may have not been of the high quality needed for the image processing, and there may have been complications with the image processing causing inaccurate results.


Calculations 3 and 4 were both very small. Having these calculations so small imply that the reliability of the individual PCR replication for concluding that a person has the SNP disease or not is low. This shows that there is likely a correlation between a positive/negative final test conclusion and a positive/negative PCR reaction, respectively. This is essentially showing that there is a low probability of the patient developing the disease (A) given a positive final test conclusion (B), and vise verse, as shown with the low percentages of P(AB).

Computer-Aided Design

TinkerCAD

TinkerCAD, the browser based 3D design lab was instrumental in displaying what improvements would be made to the PRC and fluorimeter machines. With the provided PCR parts, a quick model was generated and gave a baseline design on how to modify the initial design to fit the improvements that were proposed. The interface was not an advanced program with all the bells and whistles of a program like Solid-works, but it's simple enough to not have a high barrier of entry in order to use TinkerCAD effectively. Additionally, being a directly online design lab it was possible to have multiple people interacting with designs without having to constantly upload and update after each modification.

Our Design



The improvements made to the OpenPCR is that the Flourimeter is now combined and attached to the PCR machine. The PCR machine is a closed box and the samples are placed on a tray and then slid into the machine from the side and not placed on top like the previous design. Having the samples completely enclosed by the machine allows the process to happen more quickly because the samples will be heated and cooled from all sides, and not just the bottom like with the previous design. Once the PCR is done, the tray can be removed and then placed onto the attached Flourimeter. The Flourimeter will have light already shining on the samples, and the lid of the Flourimeter will have cameras that will be already calibrated and have a standard distance. The Flourimeter will also be able to be connected to a computer so the imagines can be processed. The only changes that will have to be made to the lab is that the SBYRGreen can be added prior to the PCR machine, or it can be added right after, but before the Flourimeter. Also, once the samples have gone through the PCR machine, their lids will need to be removed so that the cameras on the lid of the Flourimeter can have a clear unobstructed view of the samples.

Feature 2: Consumables Kit

Our consumables will be packaged in a plastic tray in a styrofoam block to ensure they are not damaged in transport. The consumables in the kit will consist of:

  • Gloves
  • SYBR Green
  • Taq Polymerase
  • Micropipette
  • Tips for Micropipette
  • Primer

The plastic tray will also be labelled so as the materials can be placed back in it when they are not in use. This will prevent any mixing up of the reagents. The reagents will be pre-measured in small plastic tubes.

The pre-measurement of the reagents will prevent human error during mixing. One would simply have to pipette all of the reagent from the plastic tube to the tube being used for the PCR.

Feature 3: Hardware - PCR Machine & Fluorimeter

For this product, both the fluorimeter and PCR machines have been combined into one, easy to run system. The way this device is set up, is that the test tubes with the DNA are inserted into a rack in the first box labelled PCR. After all of the essential parts have been added to the samples, including the parts needed for the fluorimeter, and the PCR has been completed, the tubes are then moved to the subsequent box labelled Fluorimeter. The tubes are placed into a rack on the side of the device, just like the PCR machine, and individual cameras are attached to the top of the rack. Blue light illuminates every sample from the sides. After the hatch is shut and the device is turned on, the camera's will take three individual photos of every tube and download them to a file on the computer that the device is attached to.

This change in design eliminates human error because the device is completely machine operated. There is no pipetting, and, really, no area for error other than a malfunction in the device. The only possible human error could come from the initial step of the samples being added to the test tubes before the samples enter the device at all. Also, this design cuts down on time because nothing has to really be set up for the fluorimeter. Everything comes pre-calibrated and everything is already set up in the device.