'''How the Fluorescence Technique Works'''<br> | '''How the Fluorescence Technique Works'''<br> | ||
The | The technique that was used in the lab was detecting the fluorescence of the light by the wavelengths that were detected. The way the fluorometer works is by first mixing the substance of DNA and mix it with the SYBR Green dye. Place the substance onto the middle of the hydrophobic glass slide, which is placed on the fluorometer. Turn on the switch so that the blue LED light goes through the DNA that is placed on the slide. The blue LED light interacts with the green dye so that it will be able to show the green color. Now the DNA will light up with a certain shade of green and that depends on the concentration of the DNA that was placed on the glass slide. The darker or brighter the green is the higher the concentration of DNA. With images taken of the fluorescence DNA, it can be calibrated and analyzed to see the results of how intense the fluorescence is. Which can be used to see about how much the DNA concentration was in the substance. | ||
<br> | |||
<br> | <br> | ||
<!-- Note: Be sure to delete the text in brackets: ''[ ]'' --> | <!-- Note: Be sure to delete the text in brackets: ''[ ]'' --> |
Revision as of 16:06, 11 November 2013
BME 100 Fall 2013 | Home People Lab Write-Up 1 | Lab Write-Up 2 | Lab Write-Up 3 Lab Write-Up 4 | Lab Write-Up 5 | Lab Write-Up 6 Course Logistics For Instructors Photos Wiki Editing Help | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OUR TEAM
LAB 5 WRITE-UPBackground InformationSYBR Green Dye Single-Drop Fluorimeter How the Fluorescence Technique Works
ProcedureSmart Phone Camera Settings
Calibration The camera was placed in the cradle in front of the fluorimeter and the camera application selected. There was a box covering the whole set to not have any outside source of light. Based on the view of the blue light, the camera position was adjusted until the droplet would be large and centered on the screen. The distance between the drop and cradle was then measured. With a timer enabled on the camera we were able to close the lid on the box to create a closed environment. [Instructions: Describe how to set up your camera in front of the fluorimeter. Add a PHOTO of this set-up for bonus points.]
[Instructions: See worksheet page 6.]
Data AnalysisRepresentative Images of Samples [Instructions: Show an IMAGE where you drew a circle around the droplet with the freehand tool for a sample with no DNA] [Instructions: Show an IMAGE where you drew a circle around the droplet with the freehand tool for a sample with DNA (positive signal)]
Image J Values for All Samples [Instructions: See worksheet page 8. To save time on typing a new Wiki table from scratch, use THIS TOOL to auto-generate a Wiki table: Excel-to-Wiki Converter. Copy the headers and values from the Excel spreadsheet you made, paste them into the form field, click submit, copy the Wiki code that the tool generated, and replace TABLE GOES HERE (below) with your auto-generated code.]
Fitting a Straight Line [Instructions: Place an IMAGE of your Excel plot with a line of best fit here. See worksheet page 9]
|